Supported Languages
* This section was written on the assumption that the use of WIZ750SR-RS232 evaluation board.
The WIZ750SR-232 evaluation board package contains the following parts.
The entire list of parts of the board is available at the WIZ750SR Overview: Product Contents page.
Network Settings | Local | IP address | 192.168.11.2 | - |
---|---|---|---|---|
Gateway address | 192.168.11.1 | - | ||
Subnet mask | 255.255.255.0 | - | ||
DNS server | 8.8.8.8 | Google Public DNS | ||
Port number | 5000 | - | ||
Remote | IP address | 192.168.11.3 | - | |
Port number | 5000 | - |
Serial Port Settings | Data UART | 115200-8-N-1 / Flow Control: None | - |
---|---|---|---|
Debug UART | 115200-8-N-1 / Flow Control: None | Fixed |
User's I/O Settings | UserIO A | Analog / Input | Read only |
---|---|---|---|
UserIO B | Digital / Input | Read only | |
UserIO C | Digital / Output | Read / Write | |
UserIO D | Digital / Output | Read / Write |
Double check that the WIZ750SR and the PC, or laptop you are using to set up WIZ750SR with are both on the same Ethernet network.
* When the WIZ750SR's settings are factory default,
Network Settings | PC or laptop (= Remote) | IP address | 192.168.11.3 | - |
---|---|---|---|---|
Gateway address | 192.168.11.1 | - | ||
Subnet mask | 255.255.255.0 | - | ||
Port number | 5000 | - |
The RS-232/TTL version of WIZ750SR-EVB is designed to use the DB9 connector to connect with the user’s serial device. Therefore, it is recommended to have all Ethernet and serial ports connected to the PC when testing. If the PC does not have a serial port, please purchase a RS-232 to USB converter separately.
Connect the WIZ750SR module to evaluation board and also the cable as shown in the picture below.
Connect the 5V power adaptor or USB cable to the evaluation board and turn on the power switch.
Open the configuration tool and click the search button. If the board is turned on and connected to the same network, the MAC address or settings of the WIZ750SR module can be checked using the configuration tool.
The new WIZ750SR configuration tool can be downloaded from Github below.
Change the settings accordingly to the customer’s environment. The test shown in this document is based on factory setting.
Connect the PC as the TCP client of the user’s serial device for data communication testing. In order to do this, the serial terminal program / TCP client terminal program must be opened on the PC. The serial terminal program and TCP client program must be set as below.
The COM port for serial terminal program connection can be checked as below.
The basic data communication of the WIZ750SR can be verified as below.
Now you’re ready to use the WIZ750SR!
If there is any problem?
Please refer to our Troubleshooting Guide!
WIZ750SR series Common Documents
WIZ750SR series Downloads
WIZ750SR Individual documents
WIZ750SR-100 Individual documents
WIZ750SR-105 Individual documents
WIZ750SR-110 Individual documents